Gfa elektromaten ts959 wiring diagram. html>tm

Service Parts List 10 11 13 Filter Capacitor PCB AC Input PCB Amplifier Input PCBs . The drive unit is normally directly fitted to the door shaft. 00 mm shaft, Digital Limits, Limit Range = 60. gfa-elektromaten. The door control unit TS 971 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. gfa‐elektromaten. TS 971 | Manual Découvrez le produit Coffret de commande GFA TS 959 Elektromaten de la marque GFA Elektromaten . If the door does not OPEN change first phase rotation. Products-SP - GfA UK. 0A) SE-ELEKTROMATEN, Drive for counter balanced sectional doors, output torque 90Nm, output speed 24 rpm, max. The safe operation is only guaranteed with specified normal use. Page 1 Installation instructions Door control TS 970 Automatic control Version: 51171582 -en- Version: f / 06. All of these details are covered in the product instruction here fig. 1ph GfA Ranger 91 + TS959 standard sectional door drive with digital limits Impulse up, deadman down Easily adjustable digital limits, selfholding gearbox rated to 450Nm Available with manual override at high or low level Fully pre-wired with 5 metre control cable Supplied with 8 metres of haul chain and torque plate. Overview. 1 – 1. For all single phase ELEKTROMATEN ®:Change wiring at the connection cable plug, change core no. Control Programming. Together with the GfA+ App, the tool enables reading and display of important data from GfA door controls TS 959, TS 970 and TS 971 via smartphone or tablet PC. Feb 4, 2024 · ELECTRIC OPERATORS - GfA » OSA Door Parts Limited. Founded in Düsseldorf in 1954, around 250 people are currently employed at the site. 20, SG50 - 380V GFA SE9. Apr 6, 2023 · The new GfA catalogue is online. 2 for doors with a wired safety edge GfA TS Control Panel. Care should be taken that any seals are fitted correctly and screw couplings are tightened correctly. 3-Phase Control Panel – TS 959 – GfA. 24 WS-25,40 installation instructions manual online. View and Download Elektromaten TS 959 installation instructions manual online. Log in for pricing Part No. Page 2 GfA ELEKTROMATEN GmbH & Co. 24, 55. Under the brand name ELEKTROMATEN, we sell around 200,000 drive units and 150,000 door controls worldwide every year. One switch is required for each tone. : 10002748 10011 We undertake to transmit in response to a reasoned request by the appropriate regulatory Coffret de commande Gfa TS959. door weight 4000 N, supply voltage 3~230V/400V, hollow shaft diameter 25,4mm, with emergency hand chain for manual operation, digital limit switch DES, limit switch range E=20 revolutions max. This interactive form adapts to your specific needs, asking targeted questions about your enquiry. ELEKTROMAT SE 5. 65 DU) ou convertisseur de fréquence Explore GfA door drives and control equipment for a wide range of applications. 24-55,00 TS959 (Operator: 3x415V / 800 Nm / 24 rpm) KIT including: 1 x KE 80. A step-by-step guide, ideal for new fitters. Amplifier PCBs Specifications Schematic Diagram TECHNICAL SERVICE DEPARTMENT 11 ELKINS ROAD EAST BRUNSWICK, NJ 08816 TELEPHONE (908) 390-1130 FAX (908) 390-9152 The patented safety brake is built into the gear. Page 12: Connecting Vr/Xpl5 Multi-User Receiver After the ELEKTROMATEN® is fitted we recommend the following procedure to rapidly reach a fully functioning door. Telephone: 01 926 452452 Fax: 01 926 336417 E-mail: sales@ gfa-elektromaten. Page 28 GfA ELEKTROMATEN UK Ltd Unit 1, Titan Business Centre, Spartan Close Warwick CV34 6RR, England View and Download GFA TS 971 installation instructions manual online. TS 971 gate opener pdf manual download. View and Download GFA ELEKTROMAT SE 5. au Office Hours: Monday - Friday / 8:00 am - 5:00 pm Connect the spiral cable according to the wiring diagram. uk GfA‐ELEKTROMATEN Australia Pty Ltd P. Download GFA TS 959 Series Installation Instructions Manual Control Unit GFA TS 959 Electrical Wiring Instructions 2 pages. Typical Performance Data For all three phase ELEKTROMATEN ® even DU: Change wiring at terminal X1: 1. TST 7698. For all three phase ELEKTROMATEN ® even DU: Change wiring at terminal X1: 1. The replacement circuit board for TS 959 comes with the cover and keypad. The drive unit is fitted directly to the door shaft. GfA specialise in drives and accessories for balanced and non-balanced roller shutters, sectional doors, fire shutters and more. Instructions | GAI-Tronics 12959-001 Updates TS958 to TS959 User Manual. 1 x Output Shaft 55 mm 1 x TS 959 Push Button Control 1 x Connection Cable DES - 15m long 1 x Hauling Chain Extension (3 x 4m Chain) 1 x Motor Mount with Siding Rail Support KE ELEKTROMATEN SI . Wiring Diagram. Support. PHASE ROTATION Three-phase 3 x 400 V AC, N, PE Star connection Three-phase 3 x 230 V AC, PE Replacement PCB for TS959 by GfA Elektromaten, includes cover and keypad. de Learn how to troubleshoot and fix common fault codes on GfA TS 971 control panel for doors with wireless and wired safety edges. This combination fulfils the basic requirements for electrically-operated sectional doors, and are thus particularly economical. The door control unit TS970 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. AU21052 KIT KE 9. 5 Pins. . 24-55,00 TS959. Door control. The TS959 is equipped with circuitry to activate GAI-Tronics’ Page 2: Programming Instructions 03 Fire Door Control Systems 8 Fire Control Panel 03 – Connection Drawings DLA600, DLA800 and DLA1000 Mains Supply and Fire Control Panel Open, Stop, Close GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. The TS 971 control panel comes with an integrated radio receiver for 434 MHz radio products of different manufacturers. Hold-to-run control panel for GfA-ELEKTROMATEN® drives with DES digital limit switch or NES mechanical limit switch TS 959 – Hold-to-run control panel for DES / NES limit switches Housing Dimensions W x H 2)x D [mm]: 155 x 386 x 90 (118 ) •IP65 rated when hard wired or IP54 if CEE plug used Protection against contact provided by covers for For all three phase ELEKTROMATEN ® even DU: Change wiring at terminal X1: 1. GfA ELEKTROMATEN GmbH&Co. GFA Elektromaten TS 956 For GfA ELEKTROMATEN with mechanical limit switch NES Supply voltage: • 1N~230V, PE / 3~230V, PE 3N~400V, PE / 3~400V, PE Operating frequency: 50 / 60 Hz Control voltage: 24V AC 2 or 3 contactors Mains supply ratings for external devices: Slack-rope and pass-door switch input available 24V AC (1. In the case of ELEKTROMATEN ® with a permanent mains connection, an all-pole main switch with appropriate back-up fuse must be provided. Check Details Indupart > Parts > Motors & Manual Operation > 3-Phase Control Panel – TS 959 – GfA. KIT KE 80. Moteur avec convertisseur direct (SE 6. gfa Circuit Diagrams fig. For inverter drives FI-ELEKTROMATEN ® see page 13. Raytector system door kit. GFA-2535 TABLE OF CONTENTS Introduction Test Procedures Chassis Layout Wiring Diagram . Description: The Door Control Unit GfA Elektromaten TS959 is a deadman door control for GfA Elektromaten drives with digital limit switch DES or mechanical limit switch NES Nov 9, 2022 · The 1000mA is an uprating option for the market-leading TS971, adding to the range, which was previously only available with 350mA. Page 1 Installation instructions Door control TS 971 51171521 a 02. Typical applications include: · Roller shutters · Rolling grilles · Vertical lift doors · Sectional doors without counterbalancing · High speed doors For GfA ELEKTROMATEN with mechanical limit switch NES Supply voltage: 1N~230 V, PE / 3~230 V, PE 3N~400 V, PE / 3~400 V, PE Operating frequency: 50 Hz / 60 Hz Control voltage: 24 V AC 2 or 3 contactors Mains supply ratings for external devices: 24 V AC (1 A) Permissible temperature range: -10 °C+50 °C Housing Dimensions W x H x D [mm]: 145 Page 1 Installation instructions Door control TS 959 51171547_d_03_2014 0 0 0 0 0 0 0 0 0 0 0 5 1 1 7 1 5 4 7 XXXXX; Page 2 GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf www. 60 FI, pluggable on both sides; length of cable 1): 3 m 5 m 7 m 9 m 11 m 13 m 15 m Connection set TS / clamp Connection of the The ELEKTROMATEN® must be installed with the authorised coverings and protective devices. Box 267 Roseville 2069 NSW Electrical operating instructions ELEKTROMATEN® without reversing contactor with / without terminal box with / without magnetic brake 51171321 -c 03. Control Unit GFA TS 959 Electrical Wiring Instructions. The resistor must be connected in series with the switch in the safety edge. The patented safety brake is built into the gear. Se combine avec les coffrets de commande GFA TS970, GFA TS971 et GFA TS981. KG Wiesenstraße 81 40549 Düsseldorf www. [ . The SI "Safedrive®" range of drives are for doors which require an anti-fallback device. Description: Replacement circuit board TS 959 for the TS959 door control unit from GfA Elektromaten. GFA - GFA besturingskast TS 971. 24 WS-25,40 gate opener pdf manual download. The ELEKTROMATEN SI Safedrive® FI range has some additions GfA-Stick, GfA+ App and fault guide The GfA-Stick is available for setting and servicing works on the door. Hauteur maximum porte sectionnelle de 5m. Coffret de commande TS 959 ( ancienne version ) Radio intégrée. Also for: 1000342410012. uk sales@gfa‐elektromaten. Correct the wiring in the door junction box if necessary. 1-5) Mains supply terminal Fig. Local Office: 5/22 Beaumont Rd, Mount Kuring-gai NSW 2080, Australia Phone: 02 9882 2782 Email: support@gfa. PHASE ROTATION Three-phase 3 x 400 V AC, N, PE Star connection Three-phase 3 x 230 V AC, PE Control Unit GFA TS 959 Electrical Wiring Instructions. Installation-/ Operating instructions Door control TS 971-Ex for use in ATEX; zone 1 & 2 / zone 21 & 22 Part no. Features: Our dynamic contact form is designed to streamline the enquiry process for our customers. Check Details. 14. Fréquence 50 Hz / 60 Hz Tension d'alimentation (en V) 1N~230 V Température de fonctionnement (See diagram Fig. Properties: Protection class IP54; Integrated push button for UP-STOP-CLOSE commands; Parameter setting via selector switch with digital display GfA Elektromaten manufactures operators and controllers for industrial and building doors. gfa Circuit Diagrams The patented safety brake is built into the gear. Monday to Friday: 8. 2017 0000000 0000 51171521 XXXXX After the ELEKTROMATEN® is fitted we recommend the following procedure to rapidly reach a fully functioning door. 1+3 reciprocal. 20SG50. FC - Control Panel TS 959 – GfA Door Control Panel TS 960 (Design and functions subject to change) 51171098 / 10. Catalogue Page: 242. 00pm ELEKTROMATEN TSE are drives for counterbalanced sectional doors. Page 14: Wiring Diagram WIRING DIAGRAM Transmitter Receiver Light curtain Bridge N L1 L1 fused via F1 = 1,6 At plug-in bridge Normallyclosed contact 1k2 Bridge pass or / slack wire switch contact spiral or crash de- end-of-line cable tector plug-in bridge resistor 1k2 Terminal box Bridge Normallyopen contact 8k2 *4-Channel Available (VR/61143) Before pairing any GfA remote transmitters, parameter should be set to to instruct the TS 971 to receive GfA Rolling Code Transmitters. The TS959 is activated by user-supplied switches or relay contacts. For example, the terminal diagrams show the connection wiring for two make contacts and one break contact. Description of the TS959 door control unit from GfA Elektromaten: Dec 18, 2018 · A new Fault Guide for TS Door Controls is now available Moteur GFA SE 9. For current product offering, click here Controllers TS 959 TS 970 (Rev. 02. Agincourt Road Warwick CV34 6XZ www. Door control (63 pages) E03: Faulty Wiring – Inspect wiring connections for any signs of damage or disconnection. GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. These additional limit switches can be used as potential-free make and/or break contacts in both directions of movement of the gate. In addition to the standard "extend and retract" functions, programmable relay contacts allow for numerous safety functions and other additional functions. 2016 0 0 0 0 0 0 0 0 0 0 0 5 1 1 7 1 5 8 2 XXXXX; Page 2 GfA ELEKTROMATEN GmbH & Co. 9 or older GfA door controls from other series Switch without an integrated resistor or no switch present (see Note 1) Switch without an integrated resistor 2) or no switch present (see Note 1) On On 6 Door controls from other manufacturers See Note 2 Table: Setting Q1 and Q2 The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit switch system). 01926 452 452 . 10/2023) TS 971 TS 981 FirePro Controller Light Curtain Standard Light Curtain Heavy-Duty Light Curtain Light Curtain – Synchroni Hold-to-run control panel for GfA-ELEKTROMATEN® drives with DES digital limit switch or NES mechanical limit switch TS 959 – Hold-to-run control panel for DES / NES limit switches Housing Dimensions W x H 2)x D [mm]: 155 x 386 x 90 (118 ) •IP65 rated when hard wired or IP54 if CEE plug used Protection against contact provided by covers for GfA ELEKTROMATEN GmbH & Co. KG is a full-range supplier of drive systems for industrial doors. Door control ATEX outside Ex-Zone Hold-To-Run-Mode. 20003955 00150 GE23955/015 1. 0 kW Motor Power• Protection Class IP64 with Direct Connection• Supply voltage: 1x230V/N/PE;3x230V/PE; 3x415V/N/PE; 3x415V/PE• Integrated OPEN-STOP-CLOSE push-button• Adjustment settings via selecto NES connection cable Connection to ELEKTROMATEN drives with mechani-cal limit switch, pluggable on both sides; length of cable 1): 3 m 5 m 7 m 9 m 11 m 13 m 15 m XES connection cable Connection to ELEKTROMATEN SE 8. FC - Control Panel TS 959 – GfA Elektromaten Australia. ] <10s To pair each transmitter, select parameter and press the STOP button when is present on the TS 971 display. Check the connections at terminals X1 - X4 in the door junction box. In this video Howard Weaver walks you fault code F1. 7 KiB) Without reversing contactor : 03/2010: Door controls For Roller shutters and The ELEKTROMATEN® is equipped with three additional limit switches (S5/S6/S7). The ELEKTROMATEN® is equipped with three additional limit switches (S5/S6/S7). de info@gfa‐elektromaten. 16 GfA ELEKTROMATEN UK Ltd Unit 1, Titan Business Centre, Spartan Close Warwick CV34 6RR, England. 1 wiring diagram electrical safety edge with 8K2 resistor and normally open contact This evaluation system is made for electrical safety edges within an end-of-line resistor of 1K2. TS959 Control Panel: Coherence between power and amount of cycles for ELEKTROMATEN describes ® diagram bellow. 5 TS959; TS970; TS971; TS981 up to and including software version 2. Description: The Door Control Unit GfA Elektromaten TS959 is a deadman door control for GfA Elektromaten drives with digital limit switch DES or mechanical limit switch NES. TS 959 controller pdf manual download. Spiral cables with kink protection (②) and increased protection for special requirements (③) have been added to the OSE optical safety edges. de Door control unit for GfA Elektromaten drives with digital or mechanical limit switch, constant pressure to close operation only, with 0,7m connection cable and CEE-plug. All of these details are covered in the product instruction manual here Door control unit for GfA Elektromaten drives with digital or mechanical limit switch, constant pressure to close operation only, with 0,7m connection cable and CEE-plug. Controller Control Unit GFA TS 959 Electrical Wiring Instructions. : 1 Page 10: Phase Rotation UPWARDS if the OPEN push button is operated. In addition to the seven input switches, you may connect a reset switch to deactivate all seven tones. GFA-535 II amplifier pdf manual download. : 20003679 Version: 51171729_00002 GfA Elektromaten manufactures operators and controllers for industrial and building doors. O. The chapter has been extensively revised and completed in the range of safety edges (①). GfA TS Control Panel - fault finding guide. The ELEKTROMATEN® must be installed with the authorised coverings and protective devices. 2010 en Apr 26, 2024 · Tech tips: checking number of cycles on the gfa ts 971 control panelManual panel control Gfa ranger 51w motor kit. de GfA ELEKTROMATEN UK Ltd. 2002 GB Electrical Operating instructions Electrical operating KIT KE 80. uk This is a list of Manuals for Operators and Accessories This is not an indication of what is currently being offered. A step-by-step guide, ideal for new fitters and maintenance engineers. Page 27: Declaration Of Incorporation GfA - Gesellschaft für Antriebstechnik hereby declare that the following products are conform with the above EC Guidelines and are only intended for installation in door equipment. Follow the instructions. de info@gfa-elektromaten. 2012; Page 2 GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf www. 18. Find detailed specifications and downloads for each product. • Installation Enclosure installation page 8 • Installation Wiring the Drive to the Control page 8 LIMIT SWITCH CONNECTION Plug - in system page 9 LIMIT SWITCH CONNECTION Terminal version (until year 1997) page 9 LIMIT SWITCH May 27, 2024 · GfA ELEKTROMATEN GmbH & Co. 30am - 5. 24-25,40 ER Part no. ® Page 11: Rapid Adjustment Of The Limits View and Download Adcom GFA-535 II service manual online. Logic Control Panel TS 971 Board Excludes controller housing. KG declare under our sole responsibility that the following product complies with the above directives and is only intended for installation in a door system. TS 959 door opening system pdf manual download. In this video GfA's Robert Booth walks you through how to perform a Factory Reset on the GfA TS 971 Control Panel. ® For all three phase ELEKTROMATEN even DU: Change wiring at terminal X1: 1. Installation instructions Door control TS 971 Automatic control panel with radio Version: 51171521 -en- Version: h / 03. Door control unit for GfA Elektromaten drives with digital or mechanical limit switch, constant pressure to close operation only, with connection kit for hardwiring. The entrapment protection RAYTECTOR is suitable for doors between 1. This data includes, for example: GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. View online or download Gfa TS 981 Installation Instructions Manual. co. ELECTRIC OPERATORS - GfA » OSA Door Parts Limited. It is already equipped with an intergrated hold-to-run control. Mains supply: 1N~230 V, PE; 3N~400 V, PE 3~230 V, PE; 3~400 V, PE: Operating frequency: 50 Hz / 60 Hz: Control voltage: 24 V AC: Mains supply for Resetting a GfA TS 971 Control panel. 5 m wide 10. 5 to 10. Part The ELEKTROMATEN® is equipped with three additional limit switches (S5/S6/S7). Accessories ZB. com. In combination with GfA door controls TS 970, TS 971 or TS 981, the built-on frequency inverter (FI) offers the advantage of individually adjustable output speed with soft start as well as soft stop. • Installation Enclosure installation page 8 • Installation Wiring the Drive to the Control page 8 LIMIT SWITCH CONNECTION Plug - in system page 9 LIMIT SWITCH CONNECTION Terminal version (until year 1997) page 9 • Check Overview Control Panel TS 959• Suitable for GfA Operators with Mechanical or Digital Limit Switches (NES or DES)• UP to 3. Control Unit GFA ELEKTROMATEN TS 971 Installation Instructions Manual. 9 or older GfA door controls from other series Switch without an integrated resistor or no switch present (see Note 1) Switch without an integrated resistor 2) or no switch present (see Note 1) On On 6 Door controls from other manufacturers See Note 2 Table: Setting Q1 and Q2 View and Download GFA TS 959 installation instructions manual online. The 3 phases of the incoming supply are connected to the contactor K3 with the terminals L1/L2/L3, the neutral conductor is connected to terminal strips designated N. The DIP switches in the door junction box or WSD door-module are set incorrectly. 2. For a comprehensive list of fault codes and detailed troubleshooting guides, refer to your GFA control panel manuals or videos. Description: The Door Control Unit GfA Elektromaten TS959 is a deadman door control for GFA Elektromaten drives with digital limit switch DES or mechanical limit switch NES GfA UK Ltd, Tournament Fields Business Park, Agincourt Road, Warwick, CV34 6XZ . ELEKTROMATEN with/without reversing contactor For Sliding doors ; 51171321 (200. KG Wiesenstraße 81 • 40549 Düsseldorf www. Check the positions of all DIP switches. Drive unit SE 9. 5m cable with M40/M20 gland for non gfa enclosure (DES) 20003955 00300 GE23955/030 3m cable with M40/M20 gland for non gfa enclosure (DES) 20003955 00500 GE23955/050 5m cable with M40/M20 gland for non gfa enclosure (DES) 20003955 00700 GE23955/070 7m cable with M40/M20 gland for non gfa enclosure (DES) The cables should be connected in accordance with the primary electrical circuit diagram. de Control Unit GFA TS 959 Electrical Wiring Instructions. 2012 Status: 22. E04: Sensor Malfunction – Verify the operation of safety sensors and realign or replace if necessary. Service Parts List. vj bh on sk el tm lz sk lm ty